External beam chambers $\mu$PC1x/y

Between the muon scintillators and the TPC entrance window, two small external wire chambers, \( \mu \)PC1x and \( \mu \)PC1y will be mounted. The chambers will accurately define in the x-y plane the entrance geometry to the pressure vessel. The chamber parameters are given in table 2. The anode frames will be constructed in Gatchina.


Table 2: parameters of muon wire chambers and TPC
  \( \mu \)PC1 \( \mu \)PC2 TPC
size (mm\( ^{2} \)) 50x50 110x110 150x300
anode-cathode gap(mm) 4 3.5 3.5
anode wire spacing(mm) 2 4 4
anode wires diameter(\( \mu \)m) 25 25 25
anode frame material PCB SiO\( _{2} \) SiO\( _{2} \)
cathode wire spacing(mm) 1 1 1
cathode wires diameter(\( \mu \)m) 50 100 100
cathode frame material stainless SiO\( _{2} \) SiO\( _{2} \)
wire material W(Au) W(Au) W(Au)
strip cathode wire spacing(mm) - - 1
strip cathode width(mm) - - 4
anode readout wires 2x25 2x27 74
strip cathode readout wires - - 37