There has been a slow trend toward lower elastic proton rates also seen on both detector packages. No good explanation yet.
Spikes in the French timing spectra appear from time to time. Louis is here and will be investigating (Log Book Link).
More North American electronics errors have occurred (Log
Book Link and Log
Book Link). Disconnecting and re-connecting the
"Sync" output of the KGB (at the back of the KGB) seems sometimes to be
effective in stopping persistent errors. The continued wiggling
of the cables is eventually going to break the connectors on the LTDs
(some already seem lose to me).
One run (20246)
showed a large reduction in rates on both French and North American
detectors. Paul traced this to a brief shift in the Musson box
timing shift by about 0.5 ns. It is not clear what caused the
change in timing. A similar reduction in rates occurred for run
20291 (this should be checked for timing instability).
We should spend some time during the 4-day maintenance period to try to find a way to turn the magnet power supply off at full power without causing a fast dump and without compromising our quench protection.